Number 1 corresponds to Service Required, though you may just do it yourself. Watch Video: Ryan shows how to solve beeping DSC alarm system with a yellow light or triangle. Watch the video here: DSC 1616, 1832, 1864, Impassa, and Alexor Trouble Codes. DSC alarms provide top notch protection for you and your family. However, beeping is how your alarm communicates the trouble conditions or problems that you need to fix to.
- Dsc Alarm Trouble Codes
- Dsc Power 832 Trouble Light Beeping
- Dsc Power 832 Trouble Light
- Dsc Power 832 Trouble Light 4
Tips and Advice for Older Systems
The DSC 832 has been used for DIY alarm systems and professional installations for years. Its great features, ease of programming and reasonable price made it a favorite of many in the alarm business.
The DSC Power 832 security system is no longer in production, although systems are still available from several vendors. The panel will remain relevant for years to come, due to the sheer number that have been installed.
People often inherit a DSC 832 as part of an existing home security system when they buy a house. If you happen to be one of these people, the tips below can help you get the system up and running. With the alarm working, you may be able to avoid or postpone replacing the panel.
If your DSC system isn't in such good shape, I'll give you some thoughts on that at the bottom of this page.
Ready? Here we go!
Replacing the Alarm System Battery
Have you been awakened by your DSC alarm beeping in the middle of the night? If so, a bad battery is the most likely cause.
A dead or dying backup battery is the most common problem found with any security system, and the DSC Power 832 is no exception.
Replacing an alarm panel battery is an easy do-it-yourself task, even for a beginner. For detailed steps on how to do it, see this page on DIY Alarm System Battery Replacement.
Most DSC 832 alarm panels will have the 12-volt, 4 amp/hour (4 AH) size battery in place. This is the smaller of the two standard types used for alarm panels.
If you have to replace your battery, I advise getting the larger12-volt / 7 AH unit. It will give you more run-time than the smaller unit in case of a power outage. The DSC 832 enclosure should have plenty of room for the 7AH battery, unless other devices have been installed in it.
Previously we discussed how to Install And Run Command & Conquer Red Alert On Windows 10.This has caused extreme happiness to some Command & Conquer Red Alert die hard xennials and millennials alike, and we got tons of email asking for steps on how to install Command & Conquer Red Alert 2 on their Windows 10 rig using their old installers. Command and conquer red alert 2 on windows 10. DESCRIPTION OF RED ALERT 2 Command & Conquer: Red Alert 2 (RA2) is a strategy game (RTS) released in 2000 by Electronic Arts. The game was released for PC (Windows). The game takes place between the Allied forces and the Russians in the United States after the Second World War. Play Red Alert 2, Online CnCNet for Free. There's never been a better time to play Red Alert 2 Online. CnCNet presents Yuri's Revenge Multiplayer Online. Remember, you must own Red Alert 2 & Yuri's Revenge in order to play online CnCNet's free server. Read more on purchasing the C&C Ultimate Collection from the EA Origin store. Already own the.
Be sure to observe polarity when connecting the new battery. The red, positive terminal connects to the red battery wire, and the black negative terminal goes to the black wire.
Expect to replace the battery in your DSC alarm panel about every 3-5 years or so. Of course, when the battery begins to fail, you’ll be alerted by a beeping DSC keypad. Magical powers in the universe cause this to happen only in the middle of the night, it seems…!
How to Default a DSC 832
If you’ve acquired a DSC Power 832 as part of a home purchase, you may not know the arm/disarm code. You’ll need a valid code to do almost anything with the system, so it’s worth a little effort to figure out what it is.
If the previous owner is known, they’re usually happy to give you a code. Realtors may also have a code to let them show the house.
Installers and homeowners sometimes write the code somewhere on the main panel. Check the outside of the main panel box, as well as inside the lid. If there is a DSC alarm manual or any other paperwork, look for a 4-digit code there.
Check the kitchen drawers for any alarm panel keys. Sometimes, a code is written on a key tag or scrap of paper with the key.
If the code can’t be found, a factory default can often be performed. This will restore the panel programming to original values, including the installerand master codes.
Before attempting to do a default, you should check to see if your DSC panel is locked out. Alarm companies sometimes lock out panels to prevent other companies from reprogramming them.
How to See if Your Panel is Locked Out:
1. Completely power-down the system by disconnecting one battery lead, and unplugging the low-voltage transformer.
2. Power up the panel by plugging in the transformer.
3. Listen carefully: If you hear 8-10 clicks from the panel, it is locked out. If no clicks are heard, the panel is not locked. Reconnect the battery.
If your panel is locked out, your only practical option is to replace it.
If you discover your panel isn't locked out, you can continue with the factory default procedure.
WARNING:
A factory default will remove ALL current programming from the panel!
This will require re-programming all information for the zones, communicator, partitions, etc.
If you're not comfortable doing this, contact a local alarm company professional for help!
To Do a Hardware Default:
- Disconnect AC power, either at the circuit board terminals or by unplugging the low-voltage transformer.
- Remove one battery lead, doesn’t matter which one.
- Remove all wiring from the “PGM1” and “Zone 1” terminals.
- Use a piece of wire to connect the PGM1 and Zone 1 terminals together.
- Re-connect AC power. (Battery power will NOT default the panel.)
- Go to a keypad, and verify that the Zone 1 light is lit.
- Remove AC power, and reconnect the original wiring.
- Reconnect AC and battery power.
The default master code is 1234, and can now be used to arm and disarm the DSC Power 832 system. Get a copy of the programming manual to complete installer programming of the system, and enter the user codes you prefer.
You can find links to free DSC manuals on my alarm system manual sources page.
Dsc Alarm Trouble Codes
Checking for Open Zones on DSC 832 Keypads
DSC 832 systems with hardwire contacts can develop problems with doors and windows not “setting up”. This can be caused by sagging frames, loose fitting doors and windows, and missing magnets.
Dsc Power 832 Trouble Light Beeping
The first step is to find any problem openings and correct them. Close all the exterior doors and windows (as well as the interior garage door), then move to a keypad.
To check for open zones at a DSC Power 832 LED keypad like the PC5508, see if any zone lights are lit. If none are, all is well for the moment. If any are lit, note the zone numbers.
Open zones on a DSC 832 LCD keypad like the LCD5500 will be displayed as text. Just make a note of the zone description. If more than one zone is faulted, press the “<” or “>” keys to scroll through them.
Finding the Open Zones
If a zone list is available, you’ll be able to find the open zone(s) fairly easily.
Just go to each area shown as “open” on the DSC keypad. Look for loose, missing, or mis-aligned magnets and switches.
Also, see if any door or movable portion of a window is very loose in the frame. This can prevent the magnet and switch from lining up, causing an open zone and false alarms.
If there is nozone list, you’ll need to make one. Not to worry, it's really very easy! Here's what to do:
- Have a trusty assistant open and close each door and window in the house, one by one, while you watch the keypad.
- When opened, each door and movable window should show up as a zone light or LCD text display on the keypad.
- Write down which zone light or description appears for each opening.
- Follow the steps above to locate the problem areas.
You can download and print out a FREE copy of my Basic Alarm Zone List to use as a fill-in form to make this easier.
It has 28 lines for alarm zone information, including zone numbers, descriptions of protected areas, loop and serial numbers, and more.
Are you an alarm installer, and need a sheet to record system info for your customers?
Download a FREE copy of my Alarm Installation Record Sheet.
This has spaces to enter a homeowner or business name, address, phone numbers, and panel make and model details. The lower portion of the form is a shorter, 20-zone version of the Basic Alarm Zone List above.
Each of these PDF documents will print out as a single 8-1/2 x 11 page, and I created them both to work with any type of alarm panel - wireless, hardwired, or hybrid. Modify them as you like to suit your needs.
DSC 832 Options
Your DSC Power 832 should now have a battery in good shape, a fresh set of your own codes, and working door and window contacts.
This alone gives you a good, basic home security system.
The DSC 832 can be customized with zone expanders, enhanced alarm keypads, programming, and other options. Most of this also applies to the successor to the DSC 832, the DSC 1832.
Learn more from these pages:
The DSC Power 832
The DSC Power 1832
My DSC Home Alarm is Beeping! - Causes and Solutions
Hardwired Home Security Systems
DIY Home Security Systems
What if your DSC 832 isn't in very good condition?
Depending on what kind of 'wear and tear' your system has been through, consider these points:
- Most newer DSC keypads are backwards-compatible with older models of panel, so you can probably find a replacement for a worn-out keypad. Depending on the age and condition of the rest of the system, this could be a good option
- A new system can easily be had these days for as little as $99, or even free in some cases, provided you go with monitoring. This makes spending money on a very old or worn-out system much less cost effective than it used to be
- If you own a smartphone or other web-enabled device, consider how handy it would be to use it to remotely arm and disarm your system. Many newer systems are designed to be smartphone-compatible from the ground up. If you happen to have (or plan to have) cameras, many systems allow remote live viewing and playback on smart devices
Even after all your efforts, you may decide that your system is beyond reasonable repair. If this happens, find out what a new system would cost by getting a few Free Home Security Systems Quotes from companies in your area.
These quotes can help you decide whether to pull the plug on the old system, install a new system yourself, or step aside and let a professional security company do the work.
Return to DSC Security Systems from DSC 832
Note: Feel free to print any of the articles on this site for personal, non-commercial use. Just look for this button:
Want to learn more? Give us a call today. 604-210-4600
DSC Power Series Troubleshooting Guide
The following is a troubleshooting guide designed to provide additional information and troubleshooting tips for all the possible trouble conditions that can occur on any PowerSeries control panel (Power432, Power632, Power832 and Power864).
LED Keypad, LCD Fixed-Message Keypad
To view a trouble condition, press [*][2]. The trouble light will flash. Refer to the chart below to determine the trouble condition(s) present.
Dsc Power 832 Trouble Light
Note: Some trouble conditions provide additional information (indicated with an ‘*’ in the chart below). Press the number corresponding to the trouble condition to view the additional information.
Dsc Power 832 Trouble Light 4
LCD5500 LCD Programmable-Message Keypad
To view a trouble condition, press [*][2]. The trouble light will flash and the LCD will display the first trouble condition present. Use the arrow keys to scroll through all trouble conditions present.
Note: When additional information is available for a specific trouble condition a [*] will appear on the display. Press the [*] key to view the additional information.
Light [1] * | Service Required – press [1] for more information |
Light [2] | AC Trouble |
Light [3] | Telephone Line Trouble |
Light [4] | Failure to Communicate |
Light [5] * | Zone Fault – press [5] for more information |
Light [6] * | Zone Tamper – press [6] for more information |
Light [7] * | Wireless Device Low Battery – press [7] for more information |
Light [8] | Loss of Time or Date |
Trouble [1] – Service Required
Press [1] for to determine the specific trouble(s) present
Secondary Trouble | Reason | Troubleshooting |
---|---|---|
Trouble [1] Low Battery | The main panel battery is below 11.5 VDC. The trouble condition will not clear until the battery is at least 12.5VDC under load. |
|
Trouble [2] Bell Circuit | There is an open circuit between Bell+ and Bell- |
|
Trouble [3]General System Trouble | An open circuit is present on output #1 of the PC5204 module |
|
The PC5204 has an AUX failure |
| |
The printer connected to the PC5400 is off-line |
| |
The wireless receiver has detected excessive noise in the 433MHz range (Power432, 632, 832 only) |
| |
Trouble [4] General System Tamper | An open circuit is present on the tamper input of one or more modules |
|
Trouble [5] Module Supervision | The panel has lost communication with one or more modules on the KEYBUS or a keypad has been assigned to a different slot |
|
Trouble [6] RF Jam Detected | The wireless receiver has detected excessive noise in the 433MHz range (Power864 only) |
|
Trouble [7] PC5204 Low Battery | The PC5204 battery is below 11.5 VDC. The trouble condition will not clear until the battery is at least 12.5VDC under load. |
|
Trouble [8] PC5204 AC Failure | No AC present across the PC5204 AC terminals |
|
Trouble [2] – AC Failure
Secondary Trouble | Reason | Troubleshooting |
---|---|---|
None | No AC present across the panel AC terminals |
|
Trouble [3] – Telephone Line Trouble
Secondary Trouble | Reason | Troubleshooting |
---|---|---|
None | The phone line voltage across the main panel TIP and RING terminals is less than 3 VDC |
|
Trouble [4] – Failure to Communicate
Secondary Trouble | Reason | Troubleshooting |
---|---|---|
None | The panel has failed to communicate one or more events to the central station |
Note:
|
Trouble [5] – Zone Fault
Press [5] to determine the specific zone(s) with a fault troubleSecondary Trouble | Reason | Troubleshooting |
---|---|---|
Press [5] to view specific zone(s) in fault | An open circuit is present on one or more fire zones on the main panel or zone expander |
|
An open circuit is present on PGM2 being used as a two-wire smoke detector input |
| |
One or more wireless devices have not checked in within the programmed time |
| |
A short circuit is present on one or more zones with double end-of-line resistors enabled |
|
Trouble [6] – Zone Tamper
Press [6] to determine the specific zone(s) with a tamper troubleSecondary Trouble | Reason | Troubleshooting |
---|---|---|
Press [6] to view specific zone(s) in tamper | A tamper condition is present on one or more wireless devices |
|
A open circuit is present on one or more zones with double end-of-line resistors enabled |
|
Trouble [7] – Wireless Low Battery
Press [7] to determine the specific device with a low batterySecondary Trouble | Reason | Troubleshooting |
---|---|---|
Press [7] to view the specific wireless device(s) with a low battery trouble: 1st time – Wireless Zones | One or more wireless devices has a low battery Note – The event will not be logged to the event buffer until the wireless device low battery delay time expires – Program Section [370] |
|
Trouble [8] – Loss of Clock or Date
Secondary Trouble | Reason | Troubleshooting |
---|---|---|
None | The main panel internal clock is not set | To program the time and date:
For example: 6:00 pm, June 29, 2005 |
Request a Consultation
Protect your home with security that goes the extra mile to keep you aware and in control — from anywhere!
604-210-4600
Unit 208, 12788-76A Avenue Surrey BC V3W 1S9